Can a phase-shifted full-bridge circuit be blocked without a capacitor?

Hardware design
septiembre 04, 2020 by Arianna 841

Recently, I saw a design reference on ti's official website. It uses a phase-shifted full-bridge solution, but the voltage transformer does not add a DC blocking capacitor. Why is it?

todos los comentarios

user image

Sara Publicado en September 4, 2020

I asked before. Some people said that the current mode can be omitted. With automatic volt-second balance, the voltage mode cannot be used. Is that true?

0
user image

Antonio Publicado en September 4, 2020

You don't need to add it, but your CPU main program must have a program to filter out the DC component.

0
user image

Grayson Publicado en September 4, 2020

Adding a blocking capacitor can reduce the loss of duty cycle! But at the same time increase the voltage stress of the secondary rectifier diode..

0